ATEX And IECEx Cable Gland Explosion Proof

ATEX And IECEx Cable Gland Explosion Proof
ATEX And IECEx Cable Gland Explosion Proof ATEX And IECEx Cable Gland Explosion Proof ATEX And IECEx Cable Gland Explosion Proof ATEX And IECEx Cable Gland Explosion Proof ATEX And IECEx Cable Gland Explosion Proof

Large Image :  ATEX And IECEx Cable Gland Explosion Proof

Product Details:
Place of Origin: CHINA
Brand Name: CODT
Certification: IECEx,ETL,API,ABS
Model Number: gland
Payment & Shipping Terms:
Minimum Order Quantity: negotiable
Price: negotiable
Packaging Details: carton box standard, check the specification
Delivery Time: 5-20days
Payment Terms: T/T, L/C
Supply Ability: 500 pcs per day

ATEX And IECEx Cable Gland Explosion Proof

Description
Item Type: Gland Ip Rating: IP66
Warranty: 5 Years
Highlight:

IECEx Cable Gland Explosion Proof

,

ATEX Cable Gland Explosion Proof

,

IP66 ex proof cable gland

Hot sale cable gland manufacturer cable glands stainless steel cable gland with ATEX and IECEx

  • EX-QM01-A1

ATEX And IECEx Cable Gland Explosion Proof 0

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Single seal, suitable for unarmored cable.

Ex e, structure.

Degree of protection: IP66/IP68.

  • APPLICATION

ATEX And IECEx Cable Gland Explosion Proof 1

  • TECHNICAL DATA

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Marking ATEX

Ex eb ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperature:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread AG(mm) Overall Cable Diameter ΦB(mm) Minimum Thread Length GL(mm) Nominal Protrusion
Length L(mm)
Across Flats/Corner S(ΦE) (mm)
Metric NPT Min Max
16 M16*1.5 NPT3/8 9.5 12 16 30 27(29)
20 M20*1.5 NPT1/2 9.5 16.5 16 30 27(29)
25 M25*1.5 NPT3/4 14 20 16 38 34(37)
32 M32*1.5 NPT1 18 26 18 44 40(44)
40 M40*1.5 NPT1 1/4 24 32.5 18 46 50(55)
50 M50*1.5 NPT1 1/2 30 41 20 50 60(67)
63 M63*1.5 NPT2 40 52 21 64 68(73)
75 M75*1.5 NPT2 1/2 50 65 22 70 86(89)
90 M90*1.5 NPT3 62 77 22 80 102(105)
  • SCHEMATIC DIAGRAM

ATEX And IECEx Cable Gland Explosion Proof 2

  • ORDERING GUIDE

ATEX And IECEx Cable Gland Explosion Proof 3

  • EX-QM03-C1K

ATEX And IECEx Cable Gland Explosion Proof 4

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Single seal, suitable for armored cable.

Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)

Degree of protection: IP66/IP68

  • APPLICATION

ATEX And IECEx Cable Gland Explosion Proof 1

  • TECHNICAL DATA

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb

Ex db ⅡC Gb Ex tb ⅢC Db IP66/IP68

Marking IECEx

Ex eb ⅡC Gb

Ex db ⅡC Gb Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread AG(mm) Overall Cable Diameter Minimum Thread Length GL(mm) Nominal Protrusion
Length L(mm)
Across Flats/Corner S(ΦE) (mm)
ΦB(mm) ΦC(mm)
Metric NPT Min Max Max
16 M16*1.5 NPT3/8 9.5 12 / 16 65 24(29)
20 M20*1.5 NPT1/2 9.5 16.5 / 16 67 30(34)
25 M25*1.5 NPT3/4 14 20 / 16 71 36(40)
32 M32*1.5 NPT1 18 26 / 18 76 45(51)
40 M40*1.5 NPT1 1/4 24 32.5 / 18 76 55(61)
50 M50*1.5 NPT1 1/2 30 41 / 20 91 68(74)
63 M63*1.5 NPT2 40 52 / 21 98 86(95)
75 M75*1.5 NPT2 1/2 50 65 / 22 102 95(109)
  • SCHEMATIC DIAGRAM

ATEX And IECEx Cable Gland Explosion Proof 6

  • ORDERING GUIDE

ATEX And IECEx Cable Gland Explosion Proof 7

 

  • EX-QM04-B1K

ATEX And IECEx Cable Gland Explosion Proof 8

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Dual seal, suitable for armored cable.

Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)

Degree of protection: IP66/IP68.

  • APPLICATION

ATEX And IECEx Cable Gland Explosion Proof 9

  • TECHNICAL DATA

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Marking IECEx

Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread AG(mm) Overall Cable Diameter Minimum Thread Length GL(mm) Nominal Protrusion
Length L(mm)
Across Flats/Corner S(ΦE) (mm)
ΦB(mm) ΦC(mm)
Metric NPT Min Max Min Max
16 M16*1.5 NPT3/8 9.5 12 6.5 10.5 16 65 24(29)
20 M20*1.5 NPT1/2 9.5 16.5 10 14.5 16 67 30(34)
25 M25*1.5 NPT3/4 14 20 12.5 19.5 16 71 36(40)
32 M32*1.5 NPT1 18 26 19 25.5 18 76 45(51)
40 M40*1.5 NPT1 1/4 24 32.5 25 31 18 76 55(61)
50 M50*1.5 NPT1 1/2 30 41 31.5 43 20 91 68(74)
63 M63*1.5 NPT2 40 52 42.5 50 21 98 86(95)
75 M75*1.5 NPT2 1/2 50 65 54.5 65 22 102 95(109)
  • SCHEMATIC DIAGRAM

ATEX And IECEx Cable Gland Explosion Proof 10

  • ORDERING GUIDE

ATEX And IECEx Cable Gland Explosion Proof 11

  • EX-QM05-C1K

ATEX And IECEx Cable Gland Explosion Proof 4

 

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Single seal, suitable for armored cable.

Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)

Degree of protection: IP66/IP68.

  • APPLICATION

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Marking IECEx

Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread AG(mm) Overall Cable Diameter Minimum Thread Length L1(mm) Total Length l(mm) Across Flats/Corner S(ΦE) (mm)
ΦB(mm) ΦC(mm)
Metric NPT Min Max Max
16 M16*1.5 NPT3/8 7 16 8 15 85 24(27)
20 M20*1.5 NPT1/2 7 16 10.5 15 87 24(27)
25 M25*1.5 NPT3/4 14 20 15 15 88 30(33)
32 M32*1.5 NPT1 18 25 20 17 96 36(39)
40 M40*1.5 NPT1 1/4 24 33 27 19 105 45(50)
50 M50*1.5 NPT1 1/2 31 40 31 19 108 55(60)
63 M63*1.5 NPT2 41 50 41 20 118 68(73)
75 M75*1.5 NPT2 1/2 52 63 55 21 124 86(89)
90 M90*1.5 NPT3 65 76 65 24 128 96(99)
  • SCHEMATIC DIAGRAM

ATEX And IECEx Cable Gland Explosion Proof 13

  • ORDERING GUIDE

ATEX And IECEx Cable Gland Explosion Proof 14

  • EX-QM06-B1K

ATEX And IECEx Cable Gland Explosion Proof 4

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Dual seal, suitable for armored cable.

Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)

Degree of protection: IP66/IP68.

  • APPLICATION

ATEX And IECEx Cable Gland Explosion Proof 9

  • TECHNICAL DATA

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb/Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Marking ATEx

Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread (mm) Overall Cable Diameter Minimum Thread Length L1(mm) Total Length L(mm) Across Flats/Corner S(ΦE) (mm)
ΦB(mm) ΦC(mm)
Metric NPT Min Max Min Max
16 M16*1.5 NPT3/8 7 16 5 8 15 85 24(27)
20 M20*1.5 NPT1/2 7 16 5 10.5 15 87 24(27)
25 M25*1.5 NPT3/4 14 20 8 15 15 88 30(33)
32 M32*1.5 NPT1 18 25 11 20 17 96 36(39)
40 M40*1.5 NPT1 1/4 24 33 14 27 19 105 45(50)
50 M50*1.5 NPT1 1/2 31 40 20 31 19 108 55(60)
63 M63*1.5 NPT2 41 50 30 41 20 118 68(73)
75 M75*1.5 NPT2 1/2 52 63 42 55 21 124 86(89)
90 M90*1.5 NPT3 65 76 52 65 24 128 96(99)
  • SCHEMATIC DIAGRAM

ATEX And IECEx Cable Gland Explosion Proof 13

  • ORDERING GUIDE

ATEX And IECEx Cable Gland Explosion Proof 14

  • EX-QM10-B1

ATEX And IECEx Cable Gland Explosion Proof 19

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Single seal, suitable for unarmored cable

Ex d structure.

Degree of protection: IP66/IP68.

  • APPLICATION

ATEX And IECEx Cable Gland Explosion Proof 20

  • TECHNICAL DATA

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb/ Ex db IIC Gb

Ex tb ⅢC Db IP66/IP68

Marking ATEx

Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread (mm) Overall Cable Diameter ΦB(mm) Minimum Thread Length L1(mm) Total Length L(mm) Across Flats/Corner S(ΦE) (mm)
Metric NPT Min Max
16 M16*1.5 NPT3/8 4 7 16 62 27(29)
20 M20*1.5 NPT1/2 5 8 16 62 27(29)
25 M25*1.5 NPT3/4 8 12 16 62 30(33)
32 M32*1.5 NPT1 12 16 18 67 38(42)
40 M40*1.5 NPT1 1/4 16 24 20 77 45(50)
50 M50*1.5 NPT1 1/2 18 28 20 79 55(60)
63 M63*1.5 NPT2 25.5 38 20 81 68(73)
75 M75*1.5 NPT2 1/2 29 46 20 100 85(89)
90 M90*1.5 NPT3 41 60 21 100 98(102)
  • SCHEMATIC DIAGRAM

ATEX And IECEx Cable Gland Explosion Proof 21

  • ORDERING GUIDE

ATEX And IECEx Cable Gland Explosion Proof 22

  • EX-QM10-B1

ATEX And IECEx Cable Gland Explosion Proof 23

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Single seal, suitable for unarmored cable

Ex d structure.

Degree of protection: IP66/IP68.

  • APPLICATION

ATEX And IECEx Cable Gland Explosion Proof 24

  • TECHNICAL DATA

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb/ Ex db IIC Gb

Ex tb ⅢC Db IP66/IP68

Marking ATEx

Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread (mm) Overall Cable Diameter ΦB(mm) Minimum Thread Length L1(mm) Nominal Protrusion Length(mm) Across Flats/Corner S(ΦE) (mm)
Metric NPT Min Max
16 M16*1.5 / 5 8 15 30 24(27)
20 M20*1.5 NPT1/2 7.5 11.5 15 30 24(27)
25 M25*1.5 NPT3/4 11 14.5 15 30 30(33)
32 M32*1.5 NPT1 14 20 20 32 36(39)
40 M40*1.5 NPT1 1/4 19 20 20 32 45(50)
50 M50*1.5 NPT1 1/2 25 32 20 36 55(60)
63 M63*1.5 NPT2 31.5 42.5 20 37 68(73)
  • SCHEMATIC DIAGRAM

ATEX And IECEx Cable Gland Explosion Proof 25

  • ORDERING GUIDE

ATEX And IECEx Cable Gland Explosion Proof 26

  • EX-QM13-B1T

ATEX And IECEx Cable Gland Explosion Proof 27

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Single seal, suitable for unarmored cable

Ex d structure.

Degree of protection: IP66/IP68.

  • APPLICATION

ATEX And IECEx Cable Gland Explosion Proof 28

  • TECHNICAL DATA

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb/ Ex db IIC Gb

Ex tb ⅢC Db IP66/IP68

Marking ATEx

Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread (mm) Overall Cable Diameter ΦB(mm) Minimum Thread Length L1(mm) Nominal Protrusion Length(mm) Across Flats/Corner S(ΦE) (mm)
Metric NPT Min Max
16 M16*1.5 / 5 8 15 40 24(27)
20 M20*1.5 NPT1/2 7.5 11.5 15 40 24(27)
25 M25*1.5 NPT3/4 11 14.5 15 40 30(33)
32 M32*1.5 NPT1 14 20 20 44 36(39)
40 M40*1.5 NPT1 1/4 19 20 20 48 45(50)
50 M50*1.5 NPT1 1/2 25 32 20 49 55(60)
63 M63*1.5 NPT2 31.5 43.5 20 63 68(73)
  • SCHEMATIC DIAGRAM

ATEX And IECEx Cable Gland Explosion Proof 29

  • ORDERING GUIDE

ATEX And IECEx Cable Gland Explosion Proof 22

  • EX-QM18-C1

ATEX And IECEx Cable Gland Explosion Proof 27

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Single seal, suitable for unarmored cable

Ex d structure.

Degree of protection: IP66/IP68.

  • APPLICATION

ATEX And IECEx Cable Gland Explosion Proof 32

  • TECHNICAL DATA

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb/ Ex db IIC Gb

Ex tb ⅢC Db IP66/IP68

Marking ATEx

Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread (mm) Overall Cable Diameter ΦB(mm) Minimum Thread Length L1(mm) Nominal Protrusion Length(mm) Across Flats/Corner S(ΦE) (mm)
Metric NPT Min Max
16 M16*1.5 / 5 8 15 57 24(27)
20 M20*1.5 NPT1/2 5 8 15 57 24(27)
20 M20*1.5 NPT1/2 7.5 11.5 15 57 24(27)
25 M25*1.5 NPT3/4 11 14.5 15 57 30(33)
32 M32*1.5 NPT1 14 20 20 59 36(39)
40 M40*1.5 NPT1 1/4 19 26 20 60 45(50)
50 M50*1.5 NPT1 1/2 25 32 20 62 55(60)
63 M63*1.5 NPT2 31.5 43.5 20 73 68(73)
  • SCHEMATIC DIAGRAM

ATEX And IECEx Cable Gland Explosion Proof 33

  • ORDERING GUIDE

ATEX And IECEx Cable Gland Explosion Proof 34

 

  • EX-QM21-C1K

ATEX And IECEx Cable Gland Explosion Proof 4

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Single seal, suitable for unarmored cable.

Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)

Degree of protection: IP66/IP68.

  • APPLICATION

ATEX And IECEx Cable Gland Explosion Proof 9

  • TECHNICAL DATA

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb/Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Marking ATEx

Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread (mm) Overall Cable Diameter Minimun Thread Length L1(mm) Total Length L(mm) Across Flats/Corner S(ΦE) (mm)
ΦB(mm) ΦC(mm)
Metric NPT Min Max Max
16 M16*1.5 NPT3/8 9.5 12 7 16 66 27(29)
20 M20*1.5 NPT1/2 9.5 16.5 12 16 66 27(29)
25 M25*1.5 NPT3/4 14 20 17 16 68 34(37)
32 M32*1.5 NPT1 18 26 23 18 77 40(44)
40 M40*1.5 NPT1 1/4 24 32.5 30 18 81 50(55)
50 M50*1.5 NPT1 1/2 30 41 37 20 88 60(67)
63 M63*1.5 NPT2 40 52 52 21 96 68(73)
75 M75*1.5 NPT2 1/2 50 65 62 22 114 86(89)
90 M90*1.5 NPT3 62 77 66 22 119 102(105)
  • SCHEMATIC DIAGRAM

ATEX And IECEx Cable Gland Explosion Proof 37

  • ORDERING GUIDE

ATEX And IECEx Cable Gland Explosion Proof 26

  • EX-QM22-B1K

ATEX And IECEx Cable Gland Explosion Proof 39

  • FEATURES

ATEX and IECEx certified for safe use in potentially explosive atmospheres

Dual seal, suitable for armored cable.

Valid over the entire temperature range from -50°C to 80°C (-58 ºF to 176ºF)

Degree of protection: IP66/IP68.

  • APPLICATION

ATEX And IECEx Cable Gland Explosion Proof 9

  • TECHNICAL DATA

Marking ATEX

Ⅱ2 GD Ex eb ⅡC Gb/Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Marking ATEx

Ex eb ⅡC Gb/ Ex db ⅡC Gb

Ex tb ⅢC Db IP66/IP68

Standards

EN60079-0, EN60079-1, EN60079-7, EN60079-31, IEC 60079-0, IEC60079-1, IEC60079-7, IEC60079-31

Ambient Temperarture:-50℃ ≦ Tamb ≦ +80℃

Connection Thread:Metric Thread, NPT Thread

  • SELECTION TABLE OF CABLE GLAND
Gland Size Available Entry Thread (mm) Overall Cable Diameter Minimun Thread Length L1(mm) Total Length L(mm) Across Flats/Corner S(ΦE) (mm)
ΦB(mm) ΦC(mm)
Metric NPT Min Max Min Max
16 M16*1.5 NPT3/8 9.5 12 5 8 15 66 27(29)
20 M20*1.5 NPT1/2 9.5 16.5 8 10.5 15 66 27(29)
25 M25*1.5 NPT3/4 14 20 10 15 15 68 34(37)
32 M32*1.5 NPT1 18 26 15 19.5 19 77 40(44)
40 M40*1.5 NPT1 1/4 24 32.5 19 26 19 81 50(55)
50 M50*1.5 NPT1 1/2 30 41 26 32 19 88 60(67)
63 M63*1.5 NPT2 40 52 31.5 40 19 96 68(73)
75 M75*1.5 NPT2 1/2 50 65 38 50 19 114 86(89)
90 M90*1.5 NPT3 62 77 54.5 62 19 119 102(105)
  • SCHEMATIC DIAGRAM

ATEX And IECEx Cable Gland Explosion Proof 41

 

  • ORDERING GUIDE

ATEX And IECEx Cable Gland Explosion Proof 34

  • FAQ

    Q1. Can I have a sample order ?

    Yes, we welcome sample order to test and check quality. Mixed samples are acceptable.
    Q2. How do you ship the goods and how long does it take to arrive?
    We usually ship by DHL, UPS, FedEx or TNT. It usually takes 3-5 days to arrive. Airline and sea shipping also optional.

Contact Details
Shenzhen CODT technology co.,Ltd

Contact Person: Anne

Tel: 15986671240

Send your inquiry directly to us (0 / 3000)